Home Explosion Proof (ATEX / IECEx) Sounder & Beacon Combination (Stainless Steel) – SB125

Explosion Proof (ATEX / IECEx) Sounder & Beacon Combination (Stainless Steel) – SB125

The flameproof SB125 sounder and beacon combination is ATEX / IECEx certified for use in potentially explosive atmospheres and provides clear visual and audible status indication (can be labelled accordingly). It is constructed from 316L stainless steel.

 

Key Features

  • The explosion proof set is provided with with a combination of sounders and beacons.
  • Robust and highly reliable, the Ex assembly is designed for corrosive environments and hazardous areas.
  • The housing is moulded in Glass-Reinforced Polyester (GRP), and protected by an UV resistant paint.
  • The lens is made with borosilicate glass 3.3. The set is assembled on a stainless steel 316L backplate.

Zones

ATEX Zone 1 and Zone 2 Certified for gas / vapour and Zone 21 and Zone 22 compliant for dust / powder applications.

Applications

Oil and gas, chemical, petrochemical, pharmaceutical, marine and offshore applications.

Description
Specification

The explosion proof sounder (horn) can be set with up to three tones among 59 prerecorded tones (according to user control system). Pausing of the signal can be done by an external switch. Robust and highly reliable, the Ex horn / sounder is designed for corrosive environments and hazardous areas. The housing is made of 316L stainless steel covered with UV resistant paint. The mounting bracket is 316l Stainless steel. The explosion proof assembly set can be delivered with two different light sources:

  • LED with steady, rotary or flashing of different intensity.
  • Flashing with XENON tube of different intensity.
  • Four flashing frequencies are selectable.
  • One of the sounder plus beacons can be replaced by a push button or a junction box if required
  • The status lights can be triggered either jointly or independently.
A range of accessories is available to customise this ATEX / IECEx status light package. These include pipe mounting brackets, sunshades, tag and duty labels and other accessories

MATERIAL – Enclosure: Stainless Steel 316L, Lens: Tempered borosilicate glass 3.3

COLOUR – RED : RAL3001, BLACK : RAL9005, ORANGE : RAL2010, YELLOW : RAL1018, GREEN : RAL6032, BLUE : RAL5005, GREY : RAL7038

INGRESS PROTECTION – IP66/67

AMBIENT TEMPERATURE FOR OPERATION – T6 = – 40°C ~ + 55°C , T5 = – 40°C ~ + 60°C, T4 = – 40°C ~ + 70°C

CERTIFICATION – Nemko 13 ATEX 1566X, IECEX NEM 13.0036X

EX CODE – II 2 GD Ex d IIC T4 ~ T6 Gb, Ex tb IIIC T135°C ~T85°C

STANDARD – EN / IEC 60079-0, EN / IEC 60079-1, EN / IEC 60079-31

ATEX AREA ZONE – Gas zone: 1 & 2 Dust zone: 21 & 22

CANDELA LENS COLOUR – Red: 0.15, Amber: 0.51, Blue: 0.12, Green: 0.49, Yellow: 0.85, Clear: 1

FLASHTUBE (XENON)
TRUE LIGHT INTENSITY – 5 joules = 109 Cd, 15 joules = 395 Cd, 10 joules = 293 Cd, 21 joules = 424 Cd
PEAK LIGHT INTENSITY – 5 joules = 35970 Cd, 15 joules = 83345 Cd, 10 joules = 66804 Cd, 21 joules = 95824 Cd
LIFETIME – Emissions are reduced to 70% after 8 million flashes
FLASHING OR ROTARY FREQUENCY (0 = steady status) – 60/80/120 times/min, 100/120/150 times/min, 120/150/180 times/min
CONSUMPTION – 5 joules = 10W, 15 joules = 20W, 10 joules = 15W, 21 joules = 25W

LED
TRUE LIGHT INTENSITY – 5 W = 128 Cd • 10W = 312 Cd1
LIFETIME – >50 000 hours without luminosity decreasing
FLASHING OR ROTARY FREQUENCY (0 = steady status) – 60/75/0 times/min, 60/75/100 times/min, 75/95/0 times/min, 75/95/120 times/min
CONSUMPTION – 5W • 10W

AMBIENT HUMIDITY* – Up to 95%*

POWER SUPPLY – 12-48V DC •100-240V AC (50/60hz)

RATED IMPULSE WITHSTAND VOLTAGE – 1kV following IEC 61000-4-5

WORKING CURRENT LED
• Power, 12V DC, 24V DC, 48V DC, 110V AC, 220V AC
• 5W, 530 mA, 260 mA, 120 mA, 80 mA, 40 mA
• 10W, 1100 mA, 530 mA, 240 mA, 160 mA, 80 mA

WORKING CURRENT XENON
• Energy, 12V DC, 24V DC, 48V DC, 110V AC, 220V AC
• 5J, 460 mA, 280 mA, 140 mA, 60 mA, 35 mA
• 10J, 850 mA, 490 mA, 250 mA, 100 mA, 60 mA
• 15J, 1200 mA, 700 mA, 360 mA, 140 mA, 80 mA
• 21J, NA, 960 mA, 480 mA, 180 mA, 110 mA

* = without runoff – ** = optional (cable gland and blanking plugs can be supplied if required)

 

CONSUMPTION SOUNDER – Adjustable from 5 to 25W (factory setting 20W)
CURRENT CONSUMPTION – 0.5 to 1 A
SIGNALLING TYPE – 59 tones siren.Specific customer tones can be recorded in factory
NOISE LEVEL – Until 115 dB at 1m
CABLES ENTRY – 3 x M20, 1 x M25 + 2 x M20, 1 x 1/2’’ NPT + 2 x M20, 1 x 3/4’’ NPT + 2 x M20
TERMINAL – From 22 to 14 AWG – from 0.50 mm² to 2.5 mm²
NET WEIGHT – SB125-2: 11.90 Kg, SB125-3: 16.70 Kg, SB125-4: 20.00 Kg, SB125-5: 25.10 Kg

* = without runoff – ** = optional (cable gland and blanking plugs can be supplied if required)